Medium Voltage Switchgear

KYN28-12 Metal-Clad Switchgear

  • Sufficiently large air insulation distance, avoiding the possibility of inter-phase accidents.
  • IP4X enclosure protection level — effectively prevents the human body and external solids from approaching live parts, ensuring personal safety and reliable operation.
  • Non-magnetic conductive materials used for key high-current components, solving temperature-rise problems caused by high currents.
Max. Temperature+40°C
Min. Temperature−15°C
Altitude≤1000m

Daily average relative humidity ≤95%; monthly average relative humidity ≤90%.

KYN28-12 medium voltage metal-clad switchgear cabinet
Low Voltage Switchgear

GGD LV Complete Set Switchgear

  • 1
    Reasonable design — unitized design according to the characteristics of various switching electrical appliances, combined into functional units.
  • 2
    Universal structure, flexible assembly — C-shaped profile meets various structural forms.
  • 3
    Standard modules — standard unit module structures for protection, operation, conversion and control can be separately and arbitrarily selected and combined.
  • 4
    Safety protection — isolation between regions and mutual isolation between incoming/outgoing lines of functional units.
GGD and GCK low voltage complete switchgear panels
ModelRated Voltage (V)FrameRated Current (A)Short-Circuit Breaking (kA)Short-Time Withstand (kA/1s)Peak Withstand (kA)
GGD1380A1000151530
GGD1380B600 (630)151530
GGD1380C400151530
GGD2380A1500 (1600)303063
GGD2380B1000303063
GGD2380C600303063
GGD3380A31505050105
GGD3380B25005050105
GGD3380C20005050105
GGD4380A40008080176
GGD4380B31508080176
GGD4380C25008080176
Low Voltage Switchgear

GCK LV Complete Set Switchgear

  • 1
    Compact design — enables a relatively small space to accommodate more functional units.
  • 2
    Flexible assembly — capable of meeting the requirements of various structural forms, protection levels, and operating environments.
  • 3
    Standard module design for procurement — users can select and assemble as needed.
  • 4
    High safety — extensive use of high-strength flame-retardant engineering plastic components to enhance protection and safety performance.
ItemUnitData
Main circuit rated voltageVAC 380 (400), 660 (690)
Auxiliary circuit rated voltageVAC 220, 380 (400); DC 110, 220
Rated frequencyHz50 (60)
Rated insulation voltageV660 (1000)
Rated current — horizontal busbarA≤4000
Rated current — vertical busbar (MCC)A1000
Busbar short-time withstand (1s)kA50, 80
Busbar peak withstand (0.1s)kA105, 176
Power-frequency test — main circuit (1min)V2500
Power-frequency test — auxiliary circuit (1min)V1760
Busbar — 3-phase 4-wireA, B, C, PE, N
Busbar — 3-phase 5-wireA, B, C, PE, N
Protection degreeIP40

Rated peak withstand current expressed in kA, consistent with GGD3/GGD4 peak ratings above; reproduced as published in the source datasheet.

Specifying a switchroom or panel board?